產品展示您現在的位置: 首頁 > 產品展示 > > 美國戴安Dionex > 077974美國戴安Dionex Acclaim Carbonyl LC Column 液相色譜柱

美國戴安Dionex Acclaim Carbonyl LC Column 液相色譜柱

簡要描述:

戴安公司生產的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術優勢和方法已廣泛地應用于各個領域,其*達80%。與離子色譜相關的文章有90%均出自戴安公司生產的離子色譜儀。   
戴安公司的快速溶劑萃取儀15分鐘之內僅用15毫升溶劑既可完成對10g樣品的萃取,該技術已在環境、藥物、食品和聚合物工業等領域得到廣泛應用。

型號 077974
廠商性質 代理商
更新日期 2017-10-24

美國戴安Dionex Acclaim Carbonyl LC Column 液相色譜柱

Acclaim Carbonyl LC Column 

High Resolution HPLC of Aldehyde and Ketone Contaminants

The Thermo Scientific Acclaim* Carbonyl C18 HPLC columns are designed specifically for superior resolution and high-throughput separation for DNPH derivatives of aldehydes and ketones regulated by the U.S. Environmental Protection Agency (EPA) in methods such as EPA 554, EPA 8315, EPA 1667, EPA TO-11, and by the California Environmental Protection Agency Air Resources Board in method CARB 1004.

  • High efficiency for UHPLC performance
  • Rugged columns with good lot-to-lot reproducibility
  • Proven robust methods

Carbonyl compounds, including low molecular weight aldehydes and ketones, cause environmental and health concerns. Because of their highly volatile and reactive nature, carbonyl compounds are often converted to the dinitrophenylhydrazine (DNPH) derivatives prior to analysis. The Acclaim Carbonyl C18 columns are high-performance reversed-phase columns specifically designed for high throughput and baseline separation of thirteen DNPH derivatives of aldehydes and ketones regulated by CARB Method 1004. In addition, the same chromatographic method can be applied directly to other regulatory methods such as EPA 554, EPA 8315, and EPA TO-11.

The columns are available in three particle sizes:  2.2, 3 and 5µm. Smaller particle sizes provide high peak efficiency for fast analysis. Small internal diameter (i.d.) columns (e.g., 2.1 and 3.0 mm) consume less solvents and produce less chemical waste. For high-throughput application, the 2.1 × 100 mm column format combined with high linear velocity should be considered. When high resolution power is desired, a longer column (2.1 × 150 mm) can be used at an optimal linear velocity to achieve even better resolution.

技術參數:

Acclaim Carbonyl C18 Column Specifications
Column chemistryProprietary alkyl group
Operating pressure limit (recommended)

800 bar for 2.1 x 150mm; 2.2µm

600 bar for 2.1 x 150mm; 3.0 µm

600 bar for 2.1 x 100mm

700 bar for 3.0 x 100mm

600 bar for 3.0 x 150mm

800 bar for 3.0 x 250mm

Operating pH range (recommended)2.5–7.5
Operating flow rate range (recommended)0.4–1.4  mL/min for 3.0 mm i.d. formats
0.25–0.75  mL/min for 2.1 mm i.d. formats
Operating temperature (recommended)25 -35 °C

訂購信息:

Analytical Columns
Acclaim Carbonyl RSLC Analytical,2.2µm (2.1 x 100mm)077972
Acclaim Carbonyl RSLC Analytical,2.2µm (2.1 x 150mm)077973
Acclaim Carbonyl RSLC Analytical,2.2µm (3.0 x 100mm)077974
Acclaim Carbonyl C18 Column 3µm Analytical (2.1 x 150 mm)079011
Acclaim Carbonyl C18 Column 3µm Analytical (3.0 x 150 mm)079010
Acclaim Carbonyl C18 Column 3µm Analytical (3.0 x 250 mm079009
Acclaim Carbonyl C18 Column 5µm Analytical (4.6 x 150 mm)079008

Guard Columns
Acclaim Carbonyl C18 Column 5µm Guard (2.1 x 10 mm), 2/pk079012
Acclaim Carbonyl C18 Column 5µm Guard (3.0 x 10 mm) , 2/pk079013
Acclaim Carbonyl C18 Column 5µm Guard (4.6 x 10 mm), 2/pk079014